title: "Introducing Beamex MC6-T Temperature Calibrator"
description: "After watching this video, you will understand why we say that no other temperature calibrator can match the versatility of the Beamex MC6-T."
url: "https://www.beamex.com/videos/introducing-beamex-mc6-t-temperature-calibrator-video/"
language: "en-GB"
translations: {"sv-SE":"https://www.beamex.com/sv/video/beamex-mc6-t/md/"}
modified: "2025-07-15T13:39:39+00:00"
---

![Beamex MC6-T Multifunction Temperature Calibrator and Communicator](https://www.beamex.com/app/uploads/2022/10/beamex-mc6-t-multifunction-temperature-calibrator-and-communicator1-.png)

# Introducing Beamex MC6-T Temperature Calibrator

[Home](https://www.beamex.com/) » [Videos](https://www.beamex.com/videos/) » Introducing Beamex MC6-T Temperature Calibrator

An introduction video for the temperature calibrator [Beamex MC6-T](https://www.beamex.com/calibrators/beamex-mc6-t/).

After watching this video, you will understand why we say that no other temperature calibrator can match the versatility of the Beamex MC6-T. We will go through the temperature block, calibrator, communicator, user interface, documenting features and the internal battery.

The temperature block is provided with an interchangeable insert to suit different sensors to be calibrated. The unit contains an active multizone temperature control for best temperature uniformity. The hot (660) unit includes a three-zone heating, having heaters in the bottom, in the middle and at the top of the block.

The cooling (150) unit includes a dual-zone heating and cooling. This multizone temperature control ensures an excellent temperature gradient at different immersion depth It also compensates for the heat lost having several sensors inserted.

There’s a unique temperature control algorithm that provides fast heating and cooling without overshoots, improving efficiency and saving time. The cooling model is designed so that can be used to calibrate short sensors and sanitary sensors with a flange. These kinds of sensors are very common for example in food & beverage and pharmaceutical industries.

The MC6-T is made for industrial environments and is designed to minimize the effects of varying environmental conditions. Also, it is designed to eliminate the effects of any fluctuations in the AC mains power voltage.

The Beamex MC6-T has several safety features, for example, the hot unit is provided with a tilt sensor that will warn you if the unit tilted too much for accurate calibration, and it will switch off the unit if it tilted so much that it is a safety risk.

The Beamex MC6-T has an accurate internal reference temperature sensor, but you can also use an external reference probe. We provide hi-accuracy smart reference probes that can be connected to one of the measurement channels. Stability is a very important feature in temperature calibration. The Beamex MC6-T indicates the 2-sigma standard deviation of the measurements, so you can be sure that you only use valid stabile measurements.

The Beamex MC6-T is available in two temperature versions;

- Beamex MC6-150 with temperature range -30 …. 150 °C, or -22 … 302 °F
- Beamex MC6-T660 with temperature range 50 …. 660 °C, or 122 … 1220 °F.

The Beamex MC6-T has the famous Beamex MC6 multifunction process calibrator technology built-in, with some additional tweaks. You can measure 3 RTD sensors and two thermocouples simultaneously. You can also simulate RTD and thermocouple sensors to calibrate for example temperature transmitters.

There is also a variety of electrical signals that can be measured and generated, this includes voltage, current, frequency, pulses, switch. There is also an internal 24-volt loop supply available for 2-wire transmitters. You can even calibrate pressure instruments with Beamex MC6-T. There’s a built-in barometric module and you can connect external pressure modules to the connection here.

The Beamex MC6-T includes also a built-in field communicator for HART, Foundation Fieldbus and Profibus PA instruments. So, you can use the Beamex MC6-T also calibrate, configure and trim your smart instruments. No need to carry a separate communicator with you. There is large 5.7 inch multilingual color touch screen, that can be used with bare fingers, glowed hands or stylus. User interface provides a QWERTY and numerical keyboard for fast and easy usability. Alternatively, these membrane keys can also be used to control the device.

The user interface is divided into different applications for easier use:

- The first mode is the temperature calibrator and it is a quick and easy way to use the temperature block to control temperature and to measure additional channels.
- Then we have the calibrator mode that has two windows for instrument input and output.
- The documenting calibrator is used to make automated documenting calibrations.
- Data Logger is a mode that can be used to measurement and logging up to 9 simultaneous channels.
- Communicator is the mode for communicating with smart instruments.
- And finally, we have the Settings for various settings of the device. For more details on documenting features and battery, watch the full video.

[Learn more about Beamex MC6-T](https://www.beamex.com/calibrators/beamex-mc6-t/)

## Discover more related content

![Free eLearning course on temperature calibration.](https://www.beamex.com/app/uploads/2023/09/elearning-v2-960x960.jpg) Blog

### [Industrial Temperature Calibration Course \[eLearning\]](https://blog.beamex.com/temperature-calibration-course)

Learn about industrial temperature calibration without attending in-person calibration classes.

Video

### [How to calibrate a temperature sensor and transmitter with a HART output](https://www.beamex.com/videos/how-to-calibrate-a-temperature-sensor-and-transmitter/)

In this video, we will show you how to calibrate a temperature sensor and transmitter with a HART output.

White paper

### [How to calibrate a temperature switch](https://resources.beamex.com/lp-how-to-calibrate-a-temperature-switch?_gl=1%2A13efqbg%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMxNjcyOC41LjEuMTY1NjMxNzQyMi4w)

Temperature switches are commonly used in various industrial applications to control specific functions and they need to be calibrated regularly to ensure they are working accurately and reliably.

Video

### [How to calibrate a duplex temperature sensor](https://www.beamex.com/videos/how-to-calibrate-a-duplex-temperature-sensor/)

What is needed to calibrate a duplex temperature sensor automatically?

Blog

### [How to choose a calibration laboratory – 13 things to consider](https://blog.beamex.com/how-to-choose-calibration-laboratory)

What things do you need to consider when choosing a calibration laboratory for your calibrator or reference standard?

Video

### [How to calibrate two Pt100 sensors simultaneously and automatically](https://www.beamex.com/videos/how-to-calibrate-two-pt100-sensors-simultaneously-and-automatically/)

Did you know that the MC6-T have a unique feature called group calibration which allows to calibrate 3 PCS RTD sensors simultaneously?

Video

### [How to calibrate a temperature switch automatically](https://www.beamex.com/videos/how-to-calibrate-a-temperature-switch-automatically/)

Temperature switches are commonly used in various industrial applications to control specific functions. As with any measuring instrument, they need to be calibrated regularly to ensure they are working accurately and reliably.

![How to calibrate a sanitary temperature sensor automatically](https://www.beamex.com/app/uploads/2022/10/how-to-calibrate-a-sanitary-temperature-sensor-automatically-960x540.png) Video

### [How to calibrate a sanitary temperature sensor with Beamex MC6-T](https://www.beamex.com/videos/how-to-calibrate-a-sanitary-temperature-sensor-video/)

The calibration of sanitary sensors is different than calibrating normal temperature sensors. In this video, we will show you how to calibrate a short sanitary temperature sensor automatically.

![How to calibrate a Pt100 temperature sensor automatically](https://www.beamex.com/app/uploads/2022/10/how-to-calibrate-a-pt100-temperature-sensor-automatically-960x540.png) Video

### [How to calibrate a Pt100 temperature sensor with Beamex MC6-T](https://www.beamex.com/videos/how-to-calibrate-a-pt100-temperature-sensor-video/)

Temperature measurement is one of the most common measurements in the process industry and the Pt100 temperature sensors are very common sensors. Every temperature measurement loop has a temperature sensor as the first component in the loop.

Blog

### [How to calibrate a temperature switch](https://blog.beamex.com/how-to-calibrate-a-temperature-switch)

Temperature switches are commonly used in various industrial applications to control specific functions and they need to be calibrated regularly to ensure they are working accurately and reliably.

Blog

### [Sanitary Temperature Sensor Calibration](https://blog.beamex.com/sanitary-temperature-sensor-calibration)

Sanitary temperature sensors are commonly used in many industries, such as Food and Beverage, Dairy, Pharmaceutical and Life-science where it is critical that the calibration results are free from errors.

White paper

### [Uncertainty components of a temperature calibration using a dry block](https://resources.beamex.com/uncertainty-components-temperature-calibration-dry-block?_gl=1%2A122rjxy%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMyMTc1MC42LjEuMTY1NjMyMjk2MC4w)

Making a temperature calibration using a dry block seems like a pretty simple and straight forward thing to do, however there are many possible sources for uncertainty and error that should be considered.

White paper

### [Sanitary Temperature Sensor Calibration](https://resources.beamex.com/lp-sanitary-temperature-sensor-calibration?_gl=1%2A17j3to7%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMyMTc1MC42LjEuMTY1NjMyMjIxNy4w)

Sanitary temperature sensors are commonly used in many industries, such as Food and Beverage, Dairy, Pharmaceutical and Life-science. The calibration of sanitary sensors is different and way more difficult than calibrating normal temperature sensors.

Blog

### [AMS2750E Heat Treatment Standard and Calibration](https://blog.beamex.com/ams2750e-heat-treatment-standard-and-calibration)

Heat treatment is an essential process for many critical parts of an airplane and there are tight regulations and audit processes set.

White paper

### [How to calibrate temperature sensors](https://resources.beamex.com/how-to-calibrate-temperature-sensors?_gl=1%2A7y6dia%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMyMTc1MC42LjEuMTY1NjMyMjQ0Ny4w)

Why would you measure temperature, if you don’t care about the accuracy? As any measurement instrument you want to be accurate, also temperature sensors needs to be calibrated regularly.

Blog

### [Uncertainty components of a temperature calibration using a dry block](https://blog.beamex.com/uncertainty-components-temperature-calibration-dry-block)

Making a temperature calibration using a dry block seems like a pretty simple and straight forward thing to do, however there are many possible sources for uncertainty and error that should be considered.

![Beamex MC6-T Multifunction Temperature Calibrator and Communicator](https://www.beamex.com/app/uploads/2022/10/beamex-mc6-t-multifunction-temperature-calibrator-and-communicator1--960x540.png) Video

### [Introducing Beamex MC6-T Temperature Calibrator](https://www.beamex.com/videos/introducing-beamex-mc6-t-temperature-calibrator-video/)

The MC6-T is made for industrial environments and is designed to minimize the effects of varying environmental conditions. Also, it is designed to eliminate the effects of any fluctuations in the AC mains power voltage.

Blog

### [How to calibrate temperature sensors](https://blog.beamex.com/how-to-calibrate-temperature-sensors)

Why would you measure temperature, if you don’t care about the accuracy? As any measurement instrument you want to be accurate, also temperature sensors needs to be calibrated regularly.

![Beamex MC6-T Multifunction Temperature Calibrator and Communicator](https://www.beamex.com/app/uploads/2022/10/beamex-mc6-t-multifunction-temperature-calibrator-and-communicator-960x540.png) Video

### [Beamex MC6-T Multifunction Temperature Calibrator and Communicator](https://www.beamex.com/videos/beamex-mc6-t-temperature-calibrator-video/)

With the ability to generate temperature as well as to measure and simulate temperature and electrical signals, the Beamex MC6-T offers a really unique combination of functionality.

White paper

### [AMS2750E Heat Treatment Standard and Calibration](https://resources.beamex.com/lp-ams2750e-heat-treatment-and-calibration)

Heat treatment is an essential process for many critical parts of an airplane and there are tight regulations and audit processes set.

Blog

### [Thermocouple Cold (Reference) Junction Compensation](https://blog.beamex.com/thermocouple-cold-junction-compensation)

Thermocouples can be used to measure very high temperatures and are common temperature sensors in process plants and have a few benefits that makes them widely used.

Blog

### [Temperature units and temperature unit conversion](https://blog.beamex.com/temperature-units-and-temperature-unit-conversion)

Several different temperature scales and units have been developed during the recent centuries. And since different scales have been used in different parts of the world, there are still several different scales in use.

White paper

### [Thermocouple Cold (Reference) Junction Compensation](https://resources.beamex.com/thermocouple-cold-junction-compensation?_gl=1%2A1jo2vc7%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMyOTc4OC44LjEuMTY1NjMzMDYzMy4w)

Thermocouples can be used to measure very high temperatures and are common temperature sensors in process plants and have a few benefits that makes them widely used.

White paper

### [Temperature units and temperature unit conversion](https://resources.beamex.com/temperature-units-and-unit-conversion?_gl=1%2A1srlovs%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMyOTc4OC44LjEuMTY1NjMzMDU4Ny4w)

Several different temperature scales and units have been developed during the recent centuries. And since different scales have been used in different parts of the world, there are still several different scales in use.

```json
{"@context":"https://schema.org","@graph":[{"@type":"WebPage","@id":"https://www.beamex.com/videos/introducing-beamex-mc6-t-temperature-calibrator-video/","url":"https://www.beamex.com/videos/introducing-beamex-mc6-t-temperature-calibrator-video/","name":"Introducing Beamex MC6-T Temperature Calibrator - Beamex","isPartOf":{"@id":"https://www.beamex.com/#website"},"datePublished":"2022-10-24T10:49:32+00:00","dateModified":"2025-07-15T13:39:39+00:00","description":"After watching this video, you will understand why we say that no other temperature calibrator can match the versatility of the Beamex MC6-T.","breadcrumb":{"@id":"https://www.beamex.com/videos/introducing-beamex-mc6-t-temperature-calibrator-video/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https://www.beamex.com/videos/introducing-beamex-mc6-t-temperature-calibrator-video/"]}]},{"@type":"BreadcrumbList","@id":"https://www.beamex.com/videos/introducing-beamex-mc6-t-temperature-calibrator-video/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.beamex.com/"},{"@type":"ListItem","position":2,"name":"Videos","item":"https://www.beamex.com/videos/"},{"@type":"ListItem","position":3,"name":"Introducing Beamex MC6-T Temperature Calibrator"}]},{"@type":"WebSite","@id":"https://www.beamex.com/#website","url":"https://www.beamex.com/","name":"Beamex","description":"Calibration solutions, calibrators, software and services | Beamex","publisher":{"@id":"https://www.beamex.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.beamex.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https://www.beamex.com/#organization","name":"Beamex","url":"https://www.beamex.com/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https://www.beamex.com/#/schema/logo/image/","url":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","contentUrl":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","width":358,"height":62,"caption":"Beamex"},"image":{"@id":"https://www.beamex.com/#/schema/logo/image/"},"legalName":"Beamex Oy Ab","foundingDate":"1975","description":"Beamex is your trusted partner for calibration excellence, providing accurate measurements, reliable data, and traceability for a safer and less uncertain world.","telephone":"+358 10 550 5000","address":{"@type":"PostalAddress","streetAddress":"Ristisuonraitti 10","postalCode":"68600","addressLocality":"Pietarsaari","addressCountry":"FI"},"sameAs":["https://www.instagram.com/beamexcalibration","https://www.facebook.com/BeamexCalibration","https://www.linkedin.com/company/beamex/","https://blog.beamex.com/","https://www.youtube.com/BeamexCalibration","https://twitter.com/beamexglobal","https://www.crunchbase.com/organization/beamex"],"subOrganization":[{"@id":"https://www.beamex.com/#org-de"},{"@id":"https://www.beamex.com/#org-fr"},{"@id":"https://www.beamex.com/#org-uk"},{"@id":"https://www.beamex.com/#org-us"},{"@id":"https://www.beamex.com/#org-se"},{"@id":"https://www.beamex.com/#org-nl"},{"@id":"https://www.beamex.com/#org-ca"},{"@id":"https://www.beamex.com/#org-cn"}]},{"@type":"Organization","@id":"https://www.beamex.com/#org-de","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex GmbH","telephone":"+49 2161 62115 0","faxNumber":"+49 2161 62115 99","address":{"@type":"PostalAddress","streetAddress":"Am Nordpark 1","postalCode":"41069","addressLocality":"Mönchengladbach","addressCountry":"DE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-fr","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex S.A.S.","telephone":"+33 3 20 04 57 62","address":{"@type":"PostalAddress","streetAddress":"270 Avenue de la République","postalCode":"59110","addressLocality":"La Madeleine","addressCountry":"FR"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-uk","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Limited","telephone":"+44 1455 821 920","address":{"@type":"PostalAddress","streetAddress":"Unit 1, Interchange 21, Centre Court","postalCode":"LE19 1WR","addressLocality":"Leicester","addressCountry":"GB"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-us","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex, Inc.","telephone":"+1 770 951 1927","contactPoint":[{"@type":"ContactPoint","telephone":"+1 800 888 9892","contactType":"customer service","areaServed":"US"}],"address":{"@type":"PostalAddress","streetAddress":"2018 Powers Ferry Road SE, Suite 100","postalCode":"30339","addressLocality":"Atlanta","addressRegion":"GA","addressCountry":"US"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-se","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions AB","telephone":"+46 70 140 54 10","contactPoint":[{"@type":"ContactPoint","telephone":"+46 72 198 03 23","contactType":"sales","areaServed":"Götaland"},{"@type":"ContactPoint","telephone":"+46 70 140 54 10","contactType":"sales","areaServed":"Svealand"},{"@type":"ContactPoint","telephone":"+46 72 198 03 20","contactType":"sales","areaServed":"Norrland"}],"address":{"@type":"PostalAddress","postOfficeBoxNumber":"24103","postalCode":"104 51","addressLocality":"Stockholm","addressCountry":"SE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-nl","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex B.V.","telephone":"+31 76 799 8606","address":{"@type":"PostalAddress","streetAddress":"Lage Mosten 49-63","postalCode":"4822 NK","addressLocality":"Breda","addressCountry":"NL"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-ca","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions Ltd.","telephone":"+1 289 424 2639","address":{"@type":"PostalAddress","streetAddress":"2425 Matheson Boulevard East, 8th Floor, Unit 909","postalCode":"L4W 5K4","addressLocality":"Mississauga","addressRegion":"ON","addressCountry":"CA"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-cn","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Measurement Technology (Shanghai) Co., Ltd.","telephone":"+86 4000 888 980","faxNumber":"+86 21 6104 1418","address":{"@type":"PostalAddress","streetAddress":"Rm 401, #2 Bldg, 690 Bi Bo Road, Zhangjiang Hi-Tech Park","postalCode":"201203","addressLocality":"Shanghai","addressCountry":"CN"}}]}
```