title: "How to calibrate HART pressure transmitters"
description: "In this video, we will show you how to calibrate and trim (adjust) a HART pressure transmitter with the help of Beamex MC6."
url: "https://www.beamex.com/videos/how-to-calibrate-hart-pressure-transmitters-video/"
language: "en-GB"
translations: {"en-US":"https://www.beamex.com/us/calibration-videos/how-to-calibrate-hart-pressure-transmitters/md/"}
modified: "2022-12-12T13:52:33+00:00"
---

![Beamex MC6 advanced process calibrator and wireless HART transmitter](https://www.beamex.com/app/uploads/2016/06/Beamex-MC6-wireless-HART-calibration-v3-scaled-1.jpg)

# How to calibrate HART pressure transmitters

[Home](https://www.beamex.com/) » [Videos](https://www.beamex.com/videos/) » How to calibrate HART pressure transmitters

Beamex made this video together with [ISA](https://www.isa.org/) (International Society of Automation).

In this video, we will show you how to calibrate and trim (adjust) a HART pressure transmitter.

[Beamex MC6](https://www.beamex.com/calibrators/beamex-mc6/) documenting calibrator and communicator is be used in this video to measure pressure, measure 4 to 20 mA signal, provide 24V loop supply and also as a HART communicator for the trimming. A calibration hand pump is used to provide the required pressure steps.

In this recalibration, first an As Found calibration is carried out to see how accurate the transmitter is, as it was taken from the use. The calibration was carried out with 5 steps rising and falling.

During the calibration, the MC6 calibrator will show both transmitter input pressure and output current, as well as the error in each step. Once the As Found calibration has been done, the results will be stored in the MC6 calibrator memory.

The As Found calibration was found to fail, as the error at the span point was slightly more than the max permissible error (tolerance).

As the As Found calibration failed, the transmitter needed to be trimmed/adjusted. Being a HART transmitter, the trimming is done using the MC6 as HART communicator. Using the MC6 the transmitter trim methods are carried out. As MC6 contains both communicator and calibrator, no other tools are needed.

After trimming, another (As Left) calibration was carried out. In that calibration, the transmitter was found to be very well within the tolerance limits, so the calibration passed. The As Left calibration was also saved in the calibrator memory.

Later on, the calibration results can be transferred from MC6 memory into calibration software, such as [Beamex CMX](https://www.beamex.com/calibration-software/cmx/) Calibration Management software or [Beamex LOGICAL](https://www.beamex.com/calibration-software/logical/) Cloud-based calibration software.

[Learn more about Beamex MC6](https://www.beamex.com/calibrators/beamex-mc6/)

## Discover more related content

![Mobile worker](https://www.beamex.com/app/uploads/2025/07/building-trust-jan-henrik-960x640.jpg) Blog

### [Loop Calibration vs. Instrument Calibration](https://blog.beamex.com/loop-calibration-vs-instrument-calibration)

Learn the difference between loop calibration and instrument calibration, when to use each approach, and how to combine them for accurate, traceable measurements.

![Differential pressure flow measurement blog](https://www.beamex.com/app/uploads/2025/11/differential-pressure-flow-measurement.webp) Blog

### [Footprinting in Differential Pressure Transmitter Calibration](https://blog.beamex.com/footprinting-in-differential-pressure-transmitter-calibration)

Learn how static line pressure affects differential pressure transmitters and how footprinting helps ensure accurate field calibration.

Blog

### [Comparing Multifunction and Single-Function Process Calibrators](https://blog.beamex.com/comparing-multifunction-and-single-function-process-calibrators)

Learn the pros and cons of multifunction vs. single-function process calibrators, and discover which is best for your calibration needs.

![Beamex MC6 HART communicator and calibrator](https://www.beamex.com/app/uploads/2025/01/beamex-mc6-wireless-hart-calibration-v1-960x636.jpg) Blog

### [HART Communicator vs. HART Calibrator: Understanding the Key Differences](https://blog.beamex.com/hart-communicator-vs-hart-calibrator-understanding-the-key-differences)

Learn the differences of HART Communicator and HART Calibrator.

Blog

### [Industrial Pressure Calibration Course \[eLearning\]](https://blog.beamex.com/pressure-calibration-course)

In this blog post, we want to share with you our new free eLearning course on industrial pressure calibration. With this online course you can conveniently study remotely at your own pace.

Blog

### [Calibrating a square rooting pressure transmitter](https://blog.beamex.com/2015/12/10/calibrating-a-square-rooting-pressure-transmitter)

Why does the calibration fail too easily at the zero point when calibrating a square rooting pressure transmitter?

![How to calibrate a pressure transmitter fully automatically](https://www.beamex.com/app/uploads/2022/10/how-to-calibrate-a-pressure-transmitter-fully-automatically-960x540.png) Video

### [How to calibrate a pressure transmitter fully automatically](https://www.beamex.com/videos/how-to-calibrate-a-pressure-transmitter-fully-automatically/)

How to make a fully automatic calibration of a pressure transmitter using the Beamex ePG Electric Pressure Pump and the Beamex MC6 Multifunction Calibrator and Communicator.

Blog

### [Understanding Pressure Calibrator Accuracy Specifications](https://blog.beamex.com/understanding-pressure-calibrator-accuracy-specifications)

Comparing the accuracy specifications of pressure calibrators can be a challenging task because different manufacturers specify accuracy in different ways.

Blog

### [Pressure calibration basics – Pressure types](https://blog.beamex.com/pressure-calibration-basics-pressure-types)

In everyday situations, we don’t usually talk much about different pressure types, but what different types are available?

Blog

### [How to choose a calibration laboratory – 13 things to consider](https://blog.beamex.com/how-to-choose-calibration-laboratory)

What things do you need to consider when choosing a calibration laboratory for your calibrator or reference standard?

Blog

### [How to calibrate a temperature switch](https://blog.beamex.com/how-to-calibrate-a-temperature-switch)

Temperature switches are commonly used in various industrial applications to control specific functions and they need to be calibrated regularly to ensure they are working accurately and reliably.

Blog

### [Pressure Transmitter Accuracy Specifications – the small print](https://blog.beamex.com/pressure-transmitter-accuracy-specifications-the-small-print)

Most pressure transmitters are used in varying environmental conditions in the processes. Also, the temperature of the pressure media may vary widely during usage.

Blog

### [Resistance measurement; 2, 3 or 4 wire connection – How does it work and which to use?](https://blog.beamex.com/resistance-measurement-2-3-or-4-wire-connection)

What is the difference between 2, 3 and 4 wire connection and how does resistance measurement work?

Blog

### [Pressure Switch Calibration](https://blog.beamex.com/pressure-switch-calibration)

Pressure switches are very common instruments in the process industry and like many instruments, pressure switches need to be calibrated to ensure their accuracy and reliability.

Blog

### [Why and how to calibrate WirelessHART transmitters?](https://blog.beamex.com/why-and-how-to-calibrate-wirelesshart-transmitters)

The fundamental purpose of a wireless HART transmitter is the same as for other process transmitters – i.e. to measure the input process signal and convert that into an accurate output signal.

Blog

### [How to calibrate temperature sensors](https://blog.beamex.com/how-to-calibrate-temperature-sensors)

Why would you measure temperature, if you don’t care about the accuracy? As any measurement instrument you want to be accurate, also temperature sensors needs to be calibrated regularly.

Blog

### [Thermocouple Cold (Reference) Junction Compensation](https://blog.beamex.com/thermocouple-cold-junction-compensation)

Thermocouples can be used to measure very high temperatures and are common temperature sensors in process plants and have a few benefits that makes them widely used.

Blog

### [How often should instruments be calibrated?](https://blog.beamex.com/2016/01/07/how-often-should-instruments-be-calibrated)

Calibration is extremely important. If instruments drift out of their specification range, the consequences can be disastrous for a plant, resulting in costly production downtime, safety issues and even inferior quality goods.

Blog

### [Pressure units and pressure unit conversion](https://blog.beamex.com/pressure-units-and-pressure-unit-conversion)

There are a lot of different pressure units in use around the world and sometimes this can be very confusing and may cause dangerous misunderstandings.

Blog

### [How to calibrate pressure gauges – 20 things you should consider](https://blog.beamex.com/how-to-calibrate-pressure-gauges)

Pressure gauges are common instruments in the process industry and need to be calibrated regularly to assure they are accurate.

Video

### [How often should instruments be calibrated?](https://www.beamex.com/videos/how-often-should-instruments-be-calibrated-video/)

Calibration is extremely important. If instruments drift out of their specification range, the consequences can be disastrous for a plant, resulting in costly production downtime, safety issues and even inferior quality goods.

Blog

### [How often should instruments be calibrated? \[Update\]](https://blog.beamex.com/how-often-to-calibrate-update)

Calibration is extremely important. If instruments drift out of their specification range, the consequences can be disastrous for a plant, resulting in costly production downtime, safety issues and even inferior quality goods.

Blog

### [Why must also “Smart” transmitters be calibrated?](https://blog.beamex.com/why-must-also-smart-transmitters-be-calibrated)

The so called “Smart” transmitters are getting ever more popular in the process industry, but what are these “Smart” transmitters and why must they be calibrated?

![Pressure calibration with Beamex POC8 Automatic Pressure controller](https://www.beamex.com/app/uploads/2022/10/pressure-calibration-with-beamex-poc8-automatic-pressure-controller-960x540.png) Video

### [Pressure calibration with Beamex POC8 Automatic Pressure controller](https://www.beamex.com/videos/pressure-calibration-with-beamex-poc8-automatic-pressure-controller-video/)

How to perform an automated pressure calibration using Beamex POC8 and MC6 advanced field calibrator and communicator.

```json
{"@context":"https://schema.org","@graph":[{"@type":"WebPage","@id":"https://www.beamex.com/videos/how-to-calibrate-hart-pressure-transmitters-video/","url":"https://www.beamex.com/videos/how-to-calibrate-hart-pressure-transmitters-video/","name":"How to calibrate HART pressure transmitters - Beamex","isPartOf":{"@id":"https://www.beamex.com/#website"},"datePublished":"2022-10-24T08:30:52+00:00","dateModified":"2022-12-12T13:52:33+00:00","description":"In this video, we will show you how to calibrate and trim (adjust) a HART pressure transmitter with the help of Beamex MC6.","breadcrumb":{"@id":"https://www.beamex.com/videos/how-to-calibrate-hart-pressure-transmitters-video/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https://www.beamex.com/videos/how-to-calibrate-hart-pressure-transmitters-video/"]}]},{"@type":"BreadcrumbList","@id":"https://www.beamex.com/videos/how-to-calibrate-hart-pressure-transmitters-video/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.beamex.com/"},{"@type":"ListItem","position":2,"name":"Videos","item":"https://www.beamex.com/videos/"},{"@type":"ListItem","position":3,"name":"How to calibrate HART pressure transmitters"}]},{"@type":"WebSite","@id":"https://www.beamex.com/#website","url":"https://www.beamex.com/","name":"Beamex","description":"Calibration solutions, calibrators, software and services | Beamex","publisher":{"@id":"https://www.beamex.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.beamex.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https://www.beamex.com/#organization","name":"Beamex","url":"https://www.beamex.com/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https://www.beamex.com/#/schema/logo/image/","url":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","contentUrl":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","width":358,"height":62,"caption":"Beamex"},"image":{"@id":"https://www.beamex.com/#/schema/logo/image/"},"legalName":"Beamex Oy Ab","foundingDate":"1975","description":"Beamex is your trusted partner for calibration excellence, providing accurate measurements, reliable data, and traceability for a safer and less uncertain world.","telephone":"+358 10 550 5000","address":{"@type":"PostalAddress","streetAddress":"Ristisuonraitti 10","postalCode":"68600","addressLocality":"Pietarsaari","addressCountry":"FI"},"sameAs":["https://www.instagram.com/beamexcalibration","https://www.facebook.com/BeamexCalibration","https://www.linkedin.com/company/beamex/","https://blog.beamex.com/","https://www.youtube.com/BeamexCalibration","https://twitter.com/beamexglobal","https://www.crunchbase.com/organization/beamex"],"subOrganization":[{"@id":"https://www.beamex.com/#org-de"},{"@id":"https://www.beamex.com/#org-fr"},{"@id":"https://www.beamex.com/#org-uk"},{"@id":"https://www.beamex.com/#org-us"},{"@id":"https://www.beamex.com/#org-se"},{"@id":"https://www.beamex.com/#org-nl"},{"@id":"https://www.beamex.com/#org-ca"},{"@id":"https://www.beamex.com/#org-cn"}]},{"@type":"Organization","@id":"https://www.beamex.com/#org-de","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex GmbH","telephone":"+49 2161 62115 0","faxNumber":"+49 2161 62115 99","address":{"@type":"PostalAddress","streetAddress":"Am Nordpark 1","postalCode":"41069","addressLocality":"Mönchengladbach","addressCountry":"DE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-fr","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex S.A.S.","telephone":"+33 3 20 04 57 62","address":{"@type":"PostalAddress","streetAddress":"270 Avenue de la République","postalCode":"59110","addressLocality":"La Madeleine","addressCountry":"FR"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-uk","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Limited","telephone":"+44 1455 821 920","address":{"@type":"PostalAddress","streetAddress":"Unit 1, Interchange 21, Centre Court","postalCode":"LE19 1WR","addressLocality":"Leicester","addressCountry":"GB"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-us","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex, Inc.","telephone":"+1 770 951 1927","contactPoint":[{"@type":"ContactPoint","telephone":"+1 800 888 9892","contactType":"customer service","areaServed":"US"}],"address":{"@type":"PostalAddress","streetAddress":"2018 Powers Ferry Road SE, Suite 100","postalCode":"30339","addressLocality":"Atlanta","addressRegion":"GA","addressCountry":"US"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-se","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions AB","telephone":"+46 70 140 54 10","contactPoint":[{"@type":"ContactPoint","telephone":"+46 72 198 03 23","contactType":"sales","areaServed":"Götaland"},{"@type":"ContactPoint","telephone":"+46 70 140 54 10","contactType":"sales","areaServed":"Svealand"},{"@type":"ContactPoint","telephone":"+46 72 198 03 20","contactType":"sales","areaServed":"Norrland"}],"address":{"@type":"PostalAddress","postOfficeBoxNumber":"24103","postalCode":"104 51","addressLocality":"Stockholm","addressCountry":"SE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-nl","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex B.V.","telephone":"+31 76 799 8606","address":{"@type":"PostalAddress","streetAddress":"Lage Mosten 49-63","postalCode":"4822 NK","addressLocality":"Breda","addressCountry":"NL"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-ca","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions Ltd.","telephone":"+1 289 424 2639","address":{"@type":"PostalAddress","streetAddress":"2425 Matheson Boulevard East, 8th Floor, Unit 909","postalCode":"L4W 5K4","addressLocality":"Mississauga","addressRegion":"ON","addressCountry":"CA"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-cn","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Measurement Technology (Shanghai) Co., Ltd.","telephone":"+86 4000 888 980","faxNumber":"+86 21 6104 1418","address":{"@type":"PostalAddress","streetAddress":"Rm 401, #2 Bldg, 690 Bi Bo Road, Zhangjiang Hi-Tech Park","postalCode":"201203","addressLocality":"Shanghai","addressCountry":"CN"}}]}
```