title: "How to calibrate an analog temperature loop"
description: "In this video, Roy shows how to calibrate a temperature measurement loop using the Beamex MC6 and Beamex FB 150 temperature dry block."
url: "https://www.beamex.com/videos/how-to-calibrate-an-analog-temperature-loop-video/"
language: "en-GB"
translations: {"en-US":"https://www.beamex.com/us/calibration-videos/how-to-calibrate-an-analog-temperature-loop/md/"}
modified: "2022-12-12T13:51:32+00:00"
---

![Beamex MC6 calibrator, FB temperature block and CMX calibration software](https://www.beamex.com/app/uploads/2016/06/MC6-CMX-FB-group-portrait-v1-scaled-1-e1664449307604.jpg)

# How to calibrate an analog temperature loop

[Home](https://www.beamex.com/) » [Videos](https://www.beamex.com/videos/) » How to calibrate an analog temperature loop

In this short video, Roy shows how to calibrate a temperature measurement loop with analog transmitter, local display and DCS display using the [Beamex MC6](https://www.beamex.com/calibrators/beamex-mc6/) calibrator and [Beamex FB 150 temperature dry block](https://www.beamex.com/calibrators/beamex-fb/).

The MC6 will allow him to complete a fully automatic calibration. It was previously loaded with information like instruments to be tested using [Beamex CMX calibration management software](https://www.beamex.com/calibration-software/cmx/). The MC6 also provides instructions on where to plug each lead. Finally, the MC6 allows you to take calibration results and upload them into the Beamex CMX calibration software, resulting in a fully automated and paperless calibration.

The FB Field Temperature Block is an ideal temperature block for industrial field use. It is lightweight and easy to carry. It is very fast while still providing excellent accuracy.

Beamex MC6 is an advanced, high-accuracy field calibrator and communicator. It offers calibration capabilities for pressure, temperature and various electrical signals. The MC6 also contains a full fieldbus communicator for HART, FOUNDATION Fieldbus and Profibus PA instruments.

Roy Tomalino is a calibration expert with several years of experience with Beamex products. Roy has been teaching calibration management for 13 years and is currently working as a professional services engineer at Beamex US, where he conducts educational training sessions and provides technical support for Beamex customers. In Roy’s Calibration Academy you get to know more about process calibration.

[Learn more about Beamex MC6](https://www.beamex.com/calibrators/beamex-mc6/)

## Discover more related content

White paper

### [HART Communicator vs. HART Calibrator – The Key Differences](https://resources.beamex.com/lp-hart-communicator-vs-hart-calibrator)

Discover the Key Differences Between HART Communicators and HART Calibrators

![How to calibrate a pressure transmitter fully automatically](https://www.beamex.com/app/uploads/2022/10/how-to-calibrate-a-pressure-transmitter-fully-automatically-960x540.png) Video

### [How to calibrate a pressure transmitter fully automatically](https://www.beamex.com/videos/how-to-calibrate-a-pressure-transmitter-fully-automatically/)

How to make a fully automatic calibration of a pressure transmitter using the Beamex ePG Electric Pressure Pump and the Beamex MC6 Multifunction Calibrator and Communicator.

White paper

### [How to calibrate a temperature switch](https://resources.beamex.com/lp-how-to-calibrate-a-temperature-switch?_gl=1%2A13efqbg%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMxNjcyOC41LjEuMTY1NjMxNzQyMi4w)

Temperature switches are commonly used in various industrial applications to control specific functions and they need to be calibrated regularly to ensure they are working accurately and reliably.

White paper

### [Resistance measurement; 2, 3 and 4 wire connection](https://resources.beamex.com/resistance-measurement)

What is the difference between 2, 3 and 4 wire connection and how does resistance measurement work?

White paper

### [Calibrating WirelessHART transmitters](https://resources.beamex.com/calibrating-wirelesshart-transmitters)

A modern transmitter is usually advertised as being smart and very accurate. Sometimes people may say that there is no need to calibrate smart transmitters.

White paper

### [How to calibrate temperature sensors](https://resources.beamex.com/how-to-calibrate-temperature-sensors?_gl=1%2A7y6dia%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMyMTc1MC42LjEuMTY1NjMyMjQ0Ny4w)

Why would you measure temperature, if you don’t care about the accuracy? As any measurement instrument you want to be accurate, also temperature sensors needs to be calibrated regularly.

White paper

### [AMS2750E Heat Treatment Standard and Calibration](https://resources.beamex.com/lp-ams2750e-heat-treatment-and-calibration)

Heat treatment is an essential process for many critical parts of an airplane and there are tight regulations and audit processes set.

White paper

### [Thermocouple Cold (Reference) Junction Compensation](https://resources.beamex.com/thermocouple-cold-junction-compensation?_gl=1%2A1jo2vc7%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMyOTc4OC44LjEuMTY1NjMzMDYzMy4w)

Thermocouples can be used to measure very high temperatures and are common temperature sensors in process plants and have a few benefits that makes them widely used.

White paper

### [Temperature units and temperature unit conversion](https://resources.beamex.com/temperature-units-and-unit-conversion?_gl=1%2A1srlovs%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMyOTc4OC44LjEuMTY1NjMzMDU4Ny4w)

Several different temperature scales and units have been developed during the recent centuries. And since different scales have been used in different parts of the world, there are still several different scales in use.

White paper

### [How to calibrate pressure gauges – 20 things you should consider](https://resources.beamex.com/pressure-gauge-calibration?_gl=1%2A1n9asoi%2A_ga%2AMzYzMzI4NzMxLjE2NDkwNzUxMjI.%2A_ga_DFQ48QBW49%2AMTY1NjMyOTc4OC44LjEuMTY1NjMzMDUxMC4w)

Pressure gauges are common instruments in the process industry and need to be calibrated at regular intervals to assure they are accurate.

White paper

### [How often should instruments be calibrated?](https://resources.beamex.com/how-often-should-instruments-be-calibrated)

Calibration is extremely important. If instruments drift out of their specification range, the consequences can be disastrous for a plant, resulting in costly production downtime, safety issues and even inferior quality goods.

Video

### [How often should instruments be calibrated?](https://www.beamex.com/videos/how-often-should-instruments-be-calibrated-video/)

Calibration is extremely important. If instruments drift out of their specification range, the consequences can be disastrous for a plant, resulting in costly production downtime, safety issues and even inferior quality goods.

Video

### [How to update the firmware of the Beamex MC6 calibrator](https://www.beamex.com/videos/how-to-update-the-firmware-of-the-beamex-mc6-calibrator/)

In this short video, Roy shows how to easily update the firmware of the Beamex MC6 calibrator. The latest firmware updates are always available on our website download center.

Video

### [How to calibrate HART pressure transmitters](https://www.beamex.com/videos/how-to-calibrate-hart-pressure-transmitters-video/)

How to calibrate and trim a HART pressure transmitter with a HART communicator and how to document the results and print the calibration certificate.

![Temperature loop calibration and trim with the Beamex MC6](https://www.beamex.com/app/uploads/2022/10/temperature-loop-calibration-and-trim-with-the-beamex-mc6-960x540.png) Video

### [Temperature loop calibration and trim with the Beamex MC6](https://www.beamex.com/videos/temperature-loop-calibration-and-trim-with-the-beamex-mc6-video/)

How to automatically calibrate and trim a HART temperature transmitter using the Beamex MC6 calibrator and CMX calibration management software.

Video

### [How to calibrate a pressure switch](https://www.beamex.com/videos/how-to-calibrate-a-pressure-switch-video/)

How to calibrate a pressure switch with the push of one button, using the Beamex MC6 calibrator.

Video

### [How to calibrate a Foundation Fieldbus temperature loop](https://www.beamex.com/videos/how-to-calibrate-a-foundation-fieldbus-temperature-loop-video/)

How to calibrate a temperature measurement loop with FOUNDATION Fieldbus transmitter, local display and DCS display using the Beamex MC6 calibrator and Beamex FB temperature block.

Video

### [How to calibrate a Foundation Fieldbus temperature transmitter](https://www.beamex.com/videos/how-to-calibrate-a-foundation-fieldbus-temperature-transmitter-video/)

How to automatically calibrate a FOUNDATION Fieldbus temperature loop consisting of a temperature element and temperature transmitter with sensor using Beamex MC6 calibrator and Beamex FB150 temperature block.

Video

### [How to calibrate an analog temperature loop](https://www.beamex.com/videos/how-to-calibrate-an-analog-temperature-loop-video/)

How to calibrate a temperature measurement loop with analog transmitter, local display and DCS display using the Beamex MC6 calibrator and Beamex FB 150 temperature dry block.

Video

### [How to calibrate two temperature sensors simultaneously](https://www.beamex.com/videos/how-to-calibrate-two-temperature-sensors-simultaneously-video/)

How to use the Beamex MC6 advanced field calibrator and communicator to automatically calibrate two different temperature sensors using two separate temperature blocks.

Video

### [How to calibrate a pressure transmitter](https://www.beamex.com/videos/how-to-calibrate-pressure-transmitter-video/)

How to calibrate a pressure transmitter using Beamex MC6 calibrator and Beamex PGM pressure hand pump.

![How to save smart transmitter configuration - Beamex MC6](https://www.beamex.com/app/uploads/2014/11/how-to-save-smart-transmitter-configuration-beamex-mc6-video-1-960x540.png) Video

### [How to save smart transmitter configuration](https://www.beamex.com/videos/how-to-save-smart-transmitter-configuration-video/)

How to use the Beamex MC6 to read and save the configurations of a smart transmitter for later need.

Video

### [How to calibrate a multichannel Fieldbus transmitter](https://www.beamex.com/videos/how-to-calibrate-a-multichannel-fieldbus-transmitter-video/)

How to automatically calibrate a FOUNDATION Fieldbus multi-channel temperature transmitter using the Beamex MC6 and Beamex FB temperature dry block.

Video

### [How to calibrate a pressure measurement loop](https://www.beamex.com/videos/how-to-calibrate-a-pressure-measurement-loop-video/)

How to calibrate a pressure measurement loop containing pressure transmitter and control room display.

```json
{"@context":"https://schema.org","@graph":[{"@type":"WebPage","@id":"https://www.beamex.com/videos/how-to-calibrate-an-analog-temperature-loop-video/","url":"https://www.beamex.com/videos/how-to-calibrate-an-analog-temperature-loop-video/","name":"How to calibrate an analog temperature loop - Beamex","isPartOf":{"@id":"https://www.beamex.com/#website"},"datePublished":"2022-10-24T08:19:33+00:00","dateModified":"2022-12-12T13:51:32+00:00","description":"In this video, Roy shows how to calibrate a temperature measurement loop using the Beamex MC6 and Beamex FB 150 temperature dry block.","breadcrumb":{"@id":"https://www.beamex.com/videos/how-to-calibrate-an-analog-temperature-loop-video/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https://www.beamex.com/videos/how-to-calibrate-an-analog-temperature-loop-video/"]}]},{"@type":"BreadcrumbList","@id":"https://www.beamex.com/videos/how-to-calibrate-an-analog-temperature-loop-video/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.beamex.com/"},{"@type":"ListItem","position":2,"name":"Videos","item":"https://www.beamex.com/videos/"},{"@type":"ListItem","position":3,"name":"How to calibrate an analog temperature loop"}]},{"@type":"WebSite","@id":"https://www.beamex.com/#website","url":"https://www.beamex.com/","name":"Beamex","description":"Calibration solutions, calibrators, software and services | Beamex","publisher":{"@id":"https://www.beamex.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.beamex.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https://www.beamex.com/#organization","name":"Beamex","url":"https://www.beamex.com/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https://www.beamex.com/#/schema/logo/image/","url":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","contentUrl":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","width":358,"height":62,"caption":"Beamex"},"image":{"@id":"https://www.beamex.com/#/schema/logo/image/"},"legalName":"Beamex Oy Ab","foundingDate":"1975","description":"Beamex is your trusted partner for calibration excellence, providing accurate measurements, reliable data, and traceability for a safer and less uncertain world.","telephone":"+358 10 550 5000","address":{"@type":"PostalAddress","streetAddress":"Ristisuonraitti 10","postalCode":"68600","addressLocality":"Pietarsaari","addressCountry":"FI"},"sameAs":["https://www.instagram.com/beamexcalibration","https://www.facebook.com/BeamexCalibration","https://www.linkedin.com/company/beamex/","https://blog.beamex.com/","https://www.youtube.com/BeamexCalibration","https://twitter.com/beamexglobal","https://www.crunchbase.com/organization/beamex"],"subOrganization":[{"@id":"https://www.beamex.com/#org-de"},{"@id":"https://www.beamex.com/#org-fr"},{"@id":"https://www.beamex.com/#org-uk"},{"@id":"https://www.beamex.com/#org-us"},{"@id":"https://www.beamex.com/#org-se"},{"@id":"https://www.beamex.com/#org-nl"},{"@id":"https://www.beamex.com/#org-ca"},{"@id":"https://www.beamex.com/#org-cn"}]},{"@type":"Organization","@id":"https://www.beamex.com/#org-de","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex GmbH","telephone":"+49 2161 62115 0","faxNumber":"+49 2161 62115 99","address":{"@type":"PostalAddress","streetAddress":"Am Nordpark 1","postalCode":"41069","addressLocality":"Mönchengladbach","addressCountry":"DE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-fr","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex S.A.S.","telephone":"+33 3 20 04 57 62","address":{"@type":"PostalAddress","streetAddress":"270 Avenue de la République","postalCode":"59110","addressLocality":"La Madeleine","addressCountry":"FR"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-uk","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Limited","telephone":"+44 1455 821 920","address":{"@type":"PostalAddress","streetAddress":"Unit 1, Interchange 21, Centre Court","postalCode":"LE19 1WR","addressLocality":"Leicester","addressCountry":"GB"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-us","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex, Inc.","telephone":"+1 770 951 1927","contactPoint":[{"@type":"ContactPoint","telephone":"+1 800 888 9892","contactType":"customer service","areaServed":"US"}],"address":{"@type":"PostalAddress","streetAddress":"2018 Powers Ferry Road SE, Suite 100","postalCode":"30339","addressLocality":"Atlanta","addressRegion":"GA","addressCountry":"US"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-se","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions AB","telephone":"+46 70 140 54 10","contactPoint":[{"@type":"ContactPoint","telephone":"+46 72 198 03 23","contactType":"sales","areaServed":"Götaland"},{"@type":"ContactPoint","telephone":"+46 70 140 54 10","contactType":"sales","areaServed":"Svealand"},{"@type":"ContactPoint","telephone":"+46 72 198 03 20","contactType":"sales","areaServed":"Norrland"}],"address":{"@type":"PostalAddress","postOfficeBoxNumber":"24103","postalCode":"104 51","addressLocality":"Stockholm","addressCountry":"SE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-nl","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex B.V.","telephone":"+31 76 799 8606","address":{"@type":"PostalAddress","streetAddress":"Lage Mosten 49-63","postalCode":"4822 NK","addressLocality":"Breda","addressCountry":"NL"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-ca","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions Ltd.","telephone":"+1 289 424 2639","address":{"@type":"PostalAddress","streetAddress":"2425 Matheson Boulevard East, 8th Floor, Unit 909","postalCode":"L4W 5K4","addressLocality":"Mississauga","addressRegion":"ON","addressCountry":"CA"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-cn","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Measurement Technology (Shanghai) Co., Ltd.","telephone":"+86 4000 888 980","faxNumber":"+86 21 6104 1418","address":{"@type":"PostalAddress","streetAddress":"Rm 401, #2 Bldg, 690 Bi Bo Road, Zhangjiang Hi-Tech Park","postalCode":"201203","addressLocality":"Shanghai","addressCountry":"CN"}}]}
```