title: "Beamex MB"
description: "The Beamex MB is a portable temperature dry block calibrator delivering bath-level accuracy for industrial applications."
image: "https://www.beamex.com/app/uploads/2022/11/mbxxx-facing-left-v1-with-shadow.png"
url: "https://www.beamex.com/us/calibrators/beamex-mb/"
language: "en-US"
translations: {"en-GB":"https://www.beamex.com/calibrators/beamex-mb/md/","zh-CN":"https://www.beamex.cn/jiaoyanyi/beamex-mb/md/","fi":"https://www.beamex.com/fi/kalibraattorit/beamex-mb/md/","sv-SE":"https://www.beamex.com/sv/kalibratorer/beamex-mb/md/","it-IT":"https://www.beamex.com/it/calibratori/beamex-mb/md/","es-ES":"https://www.beamex.com/es/calibradores/beamex-mb/md/","de-DE":"https://www.beamex.com/de/kalibratoren/beamex-mb/md/","fr-FR":"https://www.beamex.com/fr/calibrateurs/beamex-mb/md/"}
modified: "2023-01-04T12:40:59+00:00"
---

![Beamex MB temperature block](https://www.beamex.com/app/uploads/2022/11/mbxxx-facing-left-v1-with-shadow.png)

# Beamex MB

Metrology Temperature Block

[Download brochure](https://www.beamex.com/app/uploads/2016/10/Beamex-MB-temperature-block-brochure-ENG.pdf)

[Schedule a demo](https://resources.beamex.com/en-us/schedule-a-free-demo)

[Get pricing](https://resources.beamex.com/en-us/request-a-quotation)

## A high-accuracy portable temperature block

**Features**

![Beamex MB metrology temperature calibration block](https://www.beamex.com/app/uploads/2016/08/MBxxx-laboratory-v1-scaled-1.jpg)

#### High accuracy and stability

With a conventional dry block, you typically needed an external reference
sensor if you wanted better accuracy. The Beamex MB has accurate internal
temperature measurement and display accuracy up to ±0.1°C, so you can get
high accuracy even without an external reference sensor. With its unique temperature control technology, the Beamex MB has excellent stability up to ±0.005°C

#### Built-in high-accuracy reference input

In order to receive the best accuracy from the MB, there is a possibility to
connect an external reference sensor into the reference sensor connection (R
model). This eliminates the need for a separate reference thermometer. The
reference sensor measurement is accurate up to ±0.006 °C. ITS-90 or CVD
coefficients can be used to compensate any sensor errors.

#### Axial uniformity

With the unique dual zone control and extended well depth, the Beamex MB has
an excellent axial uniformity up to ±0.02 °C.

#### Immersion Depth

The Beamex MB series provides immersion depth up to 203 mm (160 mm in
MB140), which, together with the control technology, provides more stable
calibration. Moreover, a deeper immersion depth reduces the stem conduction
error (heat loss into the atmosphere), especially at higher temperatures.

#### Loading

With the extended well depth and the dual zone temperature control feature, the
Beamex MB can correct the effect of loading and provides loading
specifications up to ±0.005 °C.

#### Communication with Beamex MC calibrators

The communication port enables communication with selected Beamex MC calibrators for automatic calibration and documentation. Combined with a Beamex MC6 calibrator, loop calibrations are possible with conventional, HART and Fieldbus temperature transmitters with sensors.

**Resources**

#### Find user manuals, brochures, declarations and more

[View all manuals and brochures in all languages >](https://www.beamex.com/us/manuals-and-brochures/)

Declaration

### [Beamex Field Temperature Block (FB series) (EU)](https://www.beamex.com/app/uploads/2022/10/fb-eu-declaration-signed.pdf)

Declaration

### [Beamex Metrology Temperature Block (MB series) (EU)](https://www.beamex.com/app/uploads/2022/10/mb-eu-declaration-signed.pdf)

Brochure

### [Beamex FB and MB Temperature blocks (US)](https://www.beamex.com/app/uploads/2022/11/beamex-fb-and-mb-temperature-blocks-usa.pdf)

The Beamex metrology temperature block (MB) is a user friendly and highly accurate temperature dry block. It delivers bath-level accuracy in a convenient dry block with temperature ranges from −45 °C … +700 °C. It enables you to take laboratory-level accuracy with you out into the field.

Manual

### [Beamex FB manual](https://www.beamex.com/app/uploads/2016/10/FB_User_Guide.pdf)

Field Temperature Blocks (FB150, FB350, and FB660) are designed to be reliable, stable heat sources that can be used in the field or laboratory. They offer accuracy, portability, and speed for nearly every field calibration application

Manual

### [Beamex MB manual](https://www.beamex.com/app/uploads/2016/10/MB_User_Guide.pdf)

Beamex Metrology Temperature Blocks (MB140, MB155, MB425, and MB700) are designed to be stable heat sources that can be used in a laboratory or field environment.

**Accessories**

![Transport case for Beamex MC6-T](https://www.beamex.com/app/uploads/2022/10/item-8129900-v1-1024x751.jpg)

### [MB accessories](https://usa.shop.beamex.com/all-products/?_bc_fsnf=1&Related+product=FB%2FMB)

**[Read more >](https://usa.shop.beamex.com/search.php?search_query=mb&section=product)**

### [Temperature calibration accessories](https://usa.shop.beamex.com/temperature-calibration/)

**[Read more >](https://usa.shop.beamex.com/temperature-calibration/)**

![Beamex MB metrology temperature calibration block](https://www.beamex.com/app/uploads/2016/08/MBxxx-laboratory-v1-scaled-1.jpg)

## Portable temperature dry block delivering bath-level accuracy

The Beamex MB metrology temperature dry block can deliver bath-level accuracy in a portable device.

Combine it with a [Beamex MC6 calibrator](https://www.beamex.com/us/calibrators/beamex-mc6/) and calibration management software to enable fully digital calibration data flow

## Available models

The R models include an internal reference thermometer with a connection for an external reference sensor.

| **Model** | **Range** |
|---|---|
| MB140 / MB140R | -45 °C … +140 °C (-49 °F… +284 °F) |
| MB155 / MB155R | -30 °C … +155 °C (-22 °F… +311 °F) |
| MB425 / MB425R | +35 °C … +425 °C (+95 °F… +797 °F) |
| MB700 / MB700R | +50 °C … +700 °C (+122 °F… +1292 °F) |

## Discover related content

![Free eLearning course on temperature calibration.](https://www.beamex.com/app/uploads/2023/09/elearning-v2-960x960.jpg) Blog

### [Industrial Temperature Calibration Course \[eLearning\]](https://blog.beamex.com/temperature-calibration-course)

Learn about industrial temperature calibration without attending in-person calibration classes.

eBook

### [Calibration Essentials: Software](https://resources.beamex.com/en-us/calibration-essentials-software)

This Calibration Essentials Software eBook contains 67 pages of guidance and insights into how calibration software can assist you in implementing best practices.

eBook

### [Calibration Essentials: Temperature](https://resources.beamex.com/en-us/calibration-essentials-temperature)

In 53 detailed pages, this book explains strategies and tactics for calibrating temperature instrumentation.

Blog

### [How to choose a calibration laboratory – 13 things to consider](https://blog.beamex.com/how-to-choose-calibration-laboratory)

What things do you need to consider when choosing a calibration laboratory for your calibrator or reference standard?

Blog

### [How to calibrate a temperature switch](https://blog.beamex.com/how-to-calibrate-a-temperature-switch)

Temperature switches are commonly used in various industrial applications to control specific functions and they need to be calibrated regularly to ensure they are working accurately and reliably.

Blog

### [Sanitary Temperature Sensor Calibration](https://blog.beamex.com/sanitary-temperature-sensor-calibration)

Sanitary temperature sensors are commonly used in many industries, such as Food and Beverage, Dairy, Pharmaceutical and Life-science where it is critical that the calibration results are free from errors.

Webinar

### [Temperature calibration – Overcoming real-life problems](https://resources.beamex.com/en-us/webinar-temperature-calibration-overcoming-real-life-problems)

This webinar highlights the real-life obstacles and difficulties that technicians face while calibrating in the field, and what can be done to improve the process for you and your results.

Blog

### [AMS2750E Heat Treatment Standard and Calibration](https://blog.beamex.com/ams2750e-heat-treatment-standard-and-calibration)

Heat treatment is an essential process for many critical parts of an airplane and there are tight regulations and audit processes set.

Blog

### [Pt100 temperature sensor – useful things to know](https://blog.beamex.com/pt100-temperature-sensor)

What is the difference between a thermocouple and a PRT sensor? How do you measure temperature sensors?

Webinar

### [Chemical Engineering & Beamex webinar: Basics of temperature calibration](https://resources.beamex.com/en-us/webinar-basics-of-temperature-calibration)

How can you successfully use a temperature dry block to calibrate sensors and what are the common and advanced temperature applications?

Blog

### [Uncertainty components of a temperature calibration using a dry block](https://blog.beamex.com/uncertainty-components-temperature-calibration-dry-block)

Making a temperature calibration using a dry block seems like a pretty simple and straight forward thing to do, however there are many possible sources for uncertainty and error that should be considered.

Blog

### [How to calibrate temperature sensors](https://blog.beamex.com/how-to-calibrate-temperature-sensors)

Why would you measure temperature, if you don’t care about the accuracy? As any measurement instrument you want to be accurate, also temperature sensors needs to be calibrated regularly.

White Paper

### [AMS2750E Heat Treatment Standard and Calibration](https://resources.beamex.com/en-us/lp-ams2750e-heat-treatment-and-calibration)

Heat treatment is an essential process for many critical parts of an airplane and there are tight regulations and audit processes set.

White Paper

### [Pt100 temperature sensor – useful things to know](https://resources.beamex.com/en-us/pt100-temperature-sensor)

What is the difference between a thermocouple and a PRT sensor? How do you measure temperature sensors?

Blog

### [Thermocouple Cold (Reference) Junction Compensation](https://blog.beamex.com/thermocouple-cold-junction-compensation)

Thermocouples can be used to measure very high temperatures and are common temperature sensors in process plants and have a few benefits that makes them widely used.

Blog

### [Temperature units and temperature unit conversion](https://blog.beamex.com/temperature-units-and-temperature-unit-conversion)

Several different temperature scales and units have been developed during the recent centuries. And since different scales have been used in different parts of the world, there are still several different scales in use.

White Paper

### [Thermocouple Cold (Reference) Junction Compensation](https://resources.beamex.com/en-us/thermocouple-cold-junction-compensation)

Thermocouples can be used to measure very high temperatures and are common temperature sensors in process plants and have a few benefits that makes them widely used.

White Paper

### [Temperature units and temperature unit conversion](https://resources.beamex.com/en-us/temperature-units-and-unit-conversion)

Several different temperature scales and units have been developed during the recent centuries. And since different scales have been used in different parts of the world, there are still several different scales in use.

Blog

### [Measuring current using a transmitter’s test connection – don’t make this mistake!](https://blog.beamex.com/measuring-current-using-a-transmitters-test-connection-dont-make-this-mistake)

Using a mA meter with an internal impedance that is too high to measure current over the transmitter’s test connection will result in erroneous measurement results.

Blog

### [How to calibrate an RTD HART temperature transmitter](https://blog.beamex.com/how-to-calibrate-an-rtd-hart-temperature-transmitter)

The temperature transmitter is a popular instrument in process plants. Like most transmitters, it needs to be calibrated to assure that it is operating accurately.

```json
{"@context":"https://schema.org","@graph":[{"@type":"WebPage","@id":"https://www.beamex.com/us/calibrators/beamex-mb/","url":"https://www.beamex.com/us/calibrators/beamex-mb/","name":"Beamex MB high accuracy temperature dry block | Beamex","isPartOf":{"@id":"https://www.beamex.com/us/#website"},"primaryImageOfPage":{"@id":"https://www.beamex.com/us/calibrators/beamex-mb/#primaryimage"},"image":{"@id":"https://www.beamex.com/us/calibrators/beamex-mb/#primaryimage"},"thumbnailUrl":"https://www.beamex.com/app/uploads/2022/11/mbxxx-facing-left-v1-with-shadow.png","datePublished":"2022-11-01T07:22:16+00:00","dateModified":"2023-01-04T12:40:59+00:00","description":"The Beamex MB is a portable temperature dry block calibrator delivering bath-level accuracy for industrial applications.","breadcrumb":{"@id":"https://www.beamex.com/us/calibrators/beamex-mb/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://www.beamex.com/us/calibrators/beamex-mb/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://www.beamex.com/us/calibrators/beamex-mb/#primaryimage","url":"https://www.beamex.com/app/uploads/2022/11/mbxxx-facing-left-v1-with-shadow.png","contentUrl":"https://www.beamex.com/app/uploads/2022/11/mbxxx-facing-left-v1-with-shadow.png","width":1103,"height":1200,"caption":"Beamex MB temperature block"},{"@type":"BreadcrumbList","@id":"https://www.beamex.com/us/calibrators/beamex-mb/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.beamex.com/us/"},{"@type":"ListItem","position":2,"name":"Calibrators","item":"https://www.beamex.com/us/calibrators/"},{"@type":"ListItem","position":3,"name":"Beamex MB"}]},{"@type":"WebSite","@id":"https://www.beamex.com/us/#website","url":"https://www.beamex.com/us/","name":"Beamex","description":"Just another WordPress site","publisher":{"@id":"https://www.beamex.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.beamex.com/us/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://www.beamex.com/#organization","name":"Beamex","url":"https://www.beamex.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://www.beamex.com/us/#/schema/logo/image/","url":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","contentUrl":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","width":358,"height":62,"caption":"Beamex"},"image":{"@id":"https://www.beamex.com/us/#/schema/logo/image/"},"legalName":"Beamex Oy Ab","foundingDate":"1975","description":"Beamex is your trusted partner for calibration excellence, providing accurate measurements, reliable data, and traceability for a safer and less uncertain world.","telephone":"+358 10 550 5000","address":{"@type":"PostalAddress","streetAddress":"Ristisuonraitti 10","postalCode":"68600","addressLocality":"Pietarsaari","addressCountry":"FI"},"sameAs":["https://www.instagram.com/beamexcalibration","https://www.facebook.com/BeamexCalibration","https://www.linkedin.com/company/beamex/","https://blog.beamex.com/","https://www.youtube.com/BeamexCalibration","https://twitter.com/beamexglobal","https://www.crunchbase.com/organization/beamex"],"subOrganization":[{"@id":"https://www.beamex.com/#org-de"},{"@id":"https://www.beamex.com/#org-fr"},{"@id":"https://www.beamex.com/#org-uk"},{"@id":"https://www.beamex.com/#org-us"},{"@id":"https://www.beamex.com/#org-se"},{"@id":"https://www.beamex.com/#org-nl"},{"@id":"https://www.beamex.com/#org-ca"},{"@id":"https://www.beamex.com/#org-cn"}]},{"@type":"Organization","@id":"https://www.beamex.com/#org-de","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex GmbH","telephone":"+49 2161 62115 0","faxNumber":"+49 2161 62115 99","address":{"@type":"PostalAddress","streetAddress":"Am Nordpark 1","postalCode":"41069","addressLocality":"Mönchengladbach","addressCountry":"DE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-fr","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex S.A.S.","telephone":"+33 3 20 04 57 62","address":{"@type":"PostalAddress","streetAddress":"270 Avenue de la République","postalCode":"59110","addressLocality":"La Madeleine","addressCountry":"FR"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-uk","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Limited","telephone":"+44 1455 821 920","address":{"@type":"PostalAddress","streetAddress":"Unit 1, Interchange 21, Centre Court","postalCode":"LE19 1WR","addressLocality":"Leicester","addressCountry":"GB"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-us","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex, Inc.","telephone":"+1 770 951 1927","contactPoint":[{"@type":"ContactPoint","telephone":"+1 800 888 9892","contactType":"customer service","areaServed":"US"}],"address":{"@type":"PostalAddress","streetAddress":"2018 Powers Ferry Road SE, Suite 100","postalCode":"30339","addressLocality":"Atlanta","addressRegion":"GA","addressCountry":"US"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-se","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions AB","telephone":"+46 70 140 54 10","contactPoint":[{"@type":"ContactPoint","telephone":"+46 72 198 03 23","contactType":"sales","areaServed":"Götaland"},{"@type":"ContactPoint","telephone":"+46 70 140 54 10","contactType":"sales","areaServed":"Svealand"},{"@type":"ContactPoint","telephone":"+46 72 198 03 20","contactType":"sales","areaServed":"Norrland"}],"address":{"@type":"PostalAddress","postOfficeBoxNumber":"24103","postalCode":"104 51","addressLocality":"Stockholm","addressCountry":"SE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-nl","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex B.V.","telephone":"+31 76 799 8606","address":{"@type":"PostalAddress","streetAddress":"Lage Mosten 49-63","postalCode":"4822 NK","addressLocality":"Breda","addressCountry":"NL"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-ca","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions Ltd.","telephone":"+1 289 424 2639","address":{"@type":"PostalAddress","streetAddress":"2425 Matheson Boulevard East, 8th Floor, Unit 909","postalCode":"L4W 5K4","addressLocality":"Mississauga","addressRegion":"ON","addressCountry":"CA"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-cn","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Measurement Technology (Shanghai) Co., Ltd.","telephone":"+86 4000 888 980","faxNumber":"+86 21 6104 1418","address":{"@type":"PostalAddress","streetAddress":"Rm 401, #2 Bldg, 690 Bi Bo Road, Zhangjiang Hi-Tech Park","postalCode":"201203","addressLocality":"Shanghai","addressCountry":"CN"}}]}
```