title: "Alabama Power, United States | Beamex CMX and MC6 case story"
description: "Discover how Alabama Power improved their calibration process with Beamex calibrators and calibration software."
url: "https://www.beamex.com/about-us/case-stories/alabama-power/"
language: "en-GB"
translations: {"en-US":"https://www.beamex.com/us/about-us/case-stories/alabama-power/md/","es-ES":"https://www.beamex.com/es/casos-reales/alabama-power/md/"}
modified: "2025-05-13T10:34:17+00:00"
---

![Beamex MC6 process calibrator and PGM calibration pump](https://www.beamex.com/app/uploads/2016/06/Power-and-energy-industry-v8-scaled-1.jpg)

## Beamex customer case story

# Alabama Power, United States

Creating a safe environment through uncompromised accuracy at Alabama Power

[Home](https://www.beamex.com/) » [Case stories](https://www.beamex.com/about-us/case-stories/) » Alabama Power, United States \| Beamex CMX and MC6 case story

## Overview

Alabama Power, a part of Southern Company, one of the United States’ largest producers of electricity, operates four utilities with Alabama Power being the second largest within the company. Over 1.4 million homes, businesses and industries in the southern two-thirds of Alabama count on Alabama Power’s reliable electricity supply and service. More than 78,000 miles of power lines carry electricity to customers throughout 44,500 square miles.

The process control of instrumentation at Plant Miller is managed by two departments. The instrument and control (I&C) department at Plant Miller is made up of engineers and I&C specialists responsible for maintaining the distributed control system (DCS). The electrical and instrumentation (E&I) department includes journeymen responsible for maintaining the plant’s process control instrumentation. The journeymen use portable calibration equipment to make adjustments on site.

[More customer case stories](https://www.beamex.com/resources/?_resource_type=case-story)

[Talk to an expert](https://resources.beamex.com/expert-request)

## The instrumentation and importance of calibration

The majority of the pressure, temperature and level transmitters at the plant come from Endress&Hauser, Rosemount, and ABB. These also include switches, PDITs, RTDs and thermocouples. All instrumentation is classified into two categories; Critical or Balance of Plant (BOP). Although BOP instruments are tasked with taking important measurements, they do not significantly impact the process or cause a substantial safety hazard. However, critical instruments measure process variables that have a significant impact on the process and safety. Some critical instruments can trip the process if they are not operating correctly. In total, there are over 1,000 critical instruments at the plant.

Calibration affects the ability to most efficiently generate power. If an instrument is functioning properly, it improves process control. The better control, the better the end product. Accurate measurements also optimize fuel consumption, the biggest expense for electricity generation. A transmitter out of tolerance could cause other areas of the process to overcompensate by working harder, using more air, more fuel or more gas, affecting the entire process. Consumption affects everything in the long term, including equipment life cycle.

> Tasks that would take a month to two months to complete, could be performed in a few weeks.
>
> Faran Rolingson, Senior Control Engineer in the I&C department at Plant Miller, US

## Managing assets and identifying areas for improvement

Faran Rolingson is a Senior Control Engineer in the I&C department at Plant Miller. He manages maintenance projects, including calibration of instrumentation for all of the units and scrubbers. Rolingson is responsible for setting up the job plan and calibration routes, which occur during routine, yearly plant outages when all of the standard calibrations are performed.

When Rolingson joined Plant Miller, calibration was a very manual process. Single function calibrators were used, and meant the E&I journeymen also had to carry a multi-meter and communicator into the process area. It was challenging for the journeymen to follow their routes while carrying the multiple tools required during high-activity outage periods. Elevators were also forced to capacity, directly impacting both safety and productivity.

All information and documentation was paper-based, making it time-consuming to gather and also introducing the risk of human error. Calibration results were manually recorded using pen and paper. Routes were decided by reviewing printed maps and drawings. The routes were based on the plant systems, which meant a route could start with a calibration on the highest elevation, followed by the next calibration on the lowest. This required the journeymen to traverse up and down 13 floors with equipment, a highly inefficient workflow. The journeymen would also have to refer to printed drawings to locate instruments, adversely impacting productivity during time critical outage cycles. The paper-based nature of the plant’s data and documentation was extremely time consuming and labor-intensive.

## Setting up for success with high standards

Rolingson accepted responsibility for the I&C portion for Plant Miller’s implementation of the company-wide SOE. It was an opportunity to centralize information and simplify the process, improve accuracy, save time, create a safer environment and make the work easier for everyone. The SOE requires plants to use an electronic database and documenting calibrators as the foundation of an automated instrument calibration program. Furthermore, the documentation system must be enterprise-level, providing the ability to be deployed over the corporate network and the capability to integrate to the company’s computerized maintenance management software, Maximo. With an impending internal audit, Rolingson had to quickly conduct a GAP Analysis to assist in evaluating various solutions on the market.

Rolingson first evaluated the calibration equipment in service and observed the accuracy specifications did not provide an acceptable Test Uncertainty Ratio (TUR) to the more modern instruments being calibrated. In evaluating procedures, traditionally test procedures consisted of 5 points up and prevented any instrument hysteresis from being identified and documented. Rolingson also found instrument location information was only contained in printed maps and not easily accessible. This required gathering as much detailed instrument information as possible and converting the data to electronic format using an Excel and Access database in order to scale requirements for potential solutions.

After researching different vendors, Beamex was the only solution offering the all in one integrated solution (hardware & software) meeting all requirements in the GAP analysis. Rolingson chose the [Beamex integrated calibration solution](https://www.beamex.com/solutions/digital-flow-of-calibration-data/), including [Beamex MC6 advanced calibrator/communicators](https://www.beamex.com/calibrators/beamex-mc6/), [temperature blocks](https://www.beamex.com/calibrators/temperature-calibrators/), [pumps](https://www.beamex.com/calibrators/beamex-pg-calibration-pumps/), and [CMX professional calibration management software](https://www.beamex.com/calibration-software/cmx/).

## Superior functionality

There were some instances where the information available for an instrument could not be verified or was somewhat incomplete. To resolve this, journeymen used the MC6 HART communicator to map data from the instrument into a tag-based format on the MC6, perform a calibration, then, create the instrument and calibration results in the database upon upload. This method allowed for an extremely efficient way to establish tags in the database with a very high degree of quality. Additionally, having all instrument data in a central, electronic database makes the planning function much more efficient. The plant’s instrumentation is organized in a hierarchical structure which makes development of highly optimized routes quick and easy.

The MC6 multifunction calibrator/communicator allowed the journeymen to reduce the numerous pieces of equipment required to a single, multifunctional unit. Managing only one piece of equipment improved the safety and efficiency of the calibration work. The journeymen found the MC6 very easy to use. The big, color touchscreen made it easy and intuitive to navigate through the different functions of the MC6, and each functional mode is easily accessed from the “Home” screen. The plant SOE requires both AS FOUND and AS LEFT data to be documented which required two tests be conducted. The MC6 provides the option to save the AS FOUND data in the AS LEFT table if no adjustment to an instrument is done, another feature of the MC6 that has reduced the amount of time required to be compliant with procedures.

The temperature and pressure switches are critical to safety in the plant. Calibration relied heavily on the skill of the journeyman to precisely determine the measurement upon physically observing switch actuation and de-actuation. This critical calibration is now completely automated with a high degree of accuracy using the MC6. There is now no reliance on the journeyman to observe the measurement and switch action simultaneously, making for a high quality calibration and ultimately much safer operating environment. Being a member of HART Communication Foundation, Beamex diligently makes instrument manufacturer’s device descriptions (DD) available for MC6 users to download and apply themselves. Previously, it was quite disruptive and time consuming to search for the correct DD for their handheld communicator.

## Realizing the benefits, return on investment

“When you are under the gun, you need to know whether it was the process, the transmitter or controls,” Rolingson states. The high accuracy specifications of the [MC6](https://www.beamex.com/calibrators/beamex-mc6/) allowed them to exceed industry-standard TURs which give the automation engineers confidence that process control instrumentation is performing as designed. The older measurement standards had an acceptable TUR when they were initially procured years ago, but the modern instrumentation in service today has evolved to be more accurate. The high accuracy of the MC6 provides a higher quality of control, improved process efficiency, and optimized fuel consumption.

**“Tasks that would take a month to two months to complete, could be performed in a few weeks,” explained Rolingson. “Time is money.”** By removing all the manual steps in the workflow, and eliminating all the paper from the dataflow, the plant has realized a documented time saving from 70%, even up to 75% in some cases, on calibrating pressure transmitters and pressure switches. Time is of the essence during an outage, so this time savings allows technicians to maximize the amount of work accomplished in the shortest amount of time, while effectively performing vital tasks and managing workflows.
Eliminating inefficient calibration work greatly reduces the risk of outage schedule overruns and delays of start-up procedures. For Alabama Power and Southern Company, this means lowering their cost while maximizing revenue generation.

## Discover more customer case stories

![Whitetower energy, Beamex case story](https://www.beamex.com/app/uploads/2026/01/exeter--960x720.jpg) Case story

### [Whitetower Energy – Secure reliable, stable power generation](https://www.beamex.com/about-us/case-stories/whitetower/)

Read how Whitetower Energy secures reliable, stable power generation for the UK grid with the Beamex calibration ecosystem.

![Nestlé Purina - Site de Veauche](https://www.beamex.com/app/uploads/2023/05/siteveauchenestle-purina-960x288.jpg) Case story

### [Nestlé Purina insources calibrations](https://www.beamex.com/about-us/case-stories/nestle-purina/)

Nestlé Purina is a global leader in the agri-food market, particularly in the pet food market. At the Veauche site in the Loire department, more than 400 employees produce cat food.

Case story

### [Westland milk products – Calibration solution that milks every last drop of value](https://www.beamex.com/about-us/case-stories/westland-milk-products/)

Read how Westland Milk Products connected their calibration system and maintenance management system with Beamex software.

Case story

### [Paquin Sensors, US – It’s all to do with quality](https://www.beamex.com/about-us/case-stories/paquin-sensors/)

Read how Paquin Sensors saves six man-hours in just one calibration case by automating their calibration process.

Case story

### [Water and wastewater facility, US – Securing safe, scalable, and traceable calibration](https://www.beamex.com/about-us/case-stories/water-and-wastewater-facility/)

Read how the US water facility saved up to 75% in labor time and significantly reduced human error with Beamex ecosystem.

Case story

### [HIF Global, Chile – Making eFuels and decarbonisation a reality](https://www.beamex.com/about-us/case-stories/hif-global/)

Read how HIF Global, the first operational eFuels facility in the world, made eFuels and decarbonisation a reality with the support of Beamex.

Case story

### [Northvolt Ett, Sweden – Closing the loop on batteries with recycling plant](https://www.beamex.com/about-us/case-stories/northvolt-ett/)

Read how Northvolt Ett built an accurate, traceable and centralized calibration process supporting a circular battery industry.

Case story

### [OCU Hornbill, UK – Traceability, efficiency, and a sharp competitive edge](https://www.beamex.com/about-us/case-stories/ocu-hornbill/)

Read how OCU Hornbill, a leading full-service provider, has taken huge strides forward in the market thanks to the combination of Beamex hardware and software.

Case story

### [Limerick & Clare Education, Ireland – Training tomorrow’s technicians](https://www.beamex.com/about-us/case-stories/lcetb-ireland/)

Read how Beamex calibration hardware and software prepares students at LCETB for roles that rely increasingly on digital tools and services.

![Glatt Air calibration technician using Beamex MC6 calibrator.](https://www.beamex.com/app/uploads/2023/02/phto-5.jpg) Case story

### [Glatt Air Techniques, US – Enhancing efficiency and ensuring customer compliance](https://www.beamex.com/about-us/case-stories/glatt-air-techniques/)

Glatt Air Techniques enhances efficiency and ensures customer compliance with Beamex

Case story

### [Zoetis’ Rathdrum site – A clean bill of calibration health](https://www.beamex.com/about-us/case-stories/zoetis/)

Beamex calibration hardware and software forms the core of a fully digital, paperless calibration ecosystem in Rathdrum, Ireland, where Zoetis manufactures active pharmaceutical ingredients (APIs) for its world-leading range of companion animal and livestock products.

Case story

### [Douglas Calibration Services, Ireland – Reducing technicians’ workload and stress](https://www.beamex.com/about-us/case-stories/douglas-calibration-services/)

Read how LOGiCAL calibration software helped Douglas Calibration Services improve quality of life for their technicians by reducing their workload and stress.

Case story

### [Endress + Hauser, Canada – Equipping a full-service calibration laboratory](https://www.beamex.com/about-us/case-stories/endress-hauser/)

A customized Beamex solution including hardware and software sits at the heart of Endress+Hauser’s state-of-the-art Customer Experience Centre in Ontario.

Case story

### [National Grid, UK – Powering up UK gas transmission asset reliability and efficiency](https://www.beamex.com/about-us/case-stories/national-grid/)

Beamex’s automated, paperless calibration solution has helped National Grid streamline its calibration processes and save a huge amount of time and money in the process.

Case story

### [Tratz Gastec GmbH, Germany – How using the right calibration equipment saves time and money](https://www.beamex.com/about-us/case-stories/tratz-gastec-gmbh/)

Tratz Gastec distinguishes itself through high flexibility, reliability, and high-quality service activities.

Case story

### [Slade Industries, Australia – Helping Slade Industries to provide their customers with efficient service](https://www.beamex.com/about-us/case-stories/slade-industries/)

Since 1975, Australian company Slade Industries has offered specialist instrumentation and calibration services to help their customers’ businesses run at optimum efficiency.

Case story

### [Peñoles Quimica del Rey, Mexico – Deploying game-changing technology for the calibration process](https://www.beamex.com/about-us/case-stories/penoles-quimica-del-rey/)

With MC6 and CMX, Peñoles Quimica del Rey have been able to reduced their carbon footprint, waste of raw materials and lowered costs.

Case story

### [MCI, Chile – Complete and high-quality service to customers](https://www.beamex.com/about-us/case-stories/mantencion-y-control-industrial-spa/)

Beamex calibrators have become fundamental in MCI’s calibration process due to their accuracy, versatility, reliability and efficiency.

Case story

### [Lawrenceburg Power, USA – Calibration in less time lowers costs](https://www.beamex.com/about-us/case-stories/lawrenceburg-power/)

Beamex calibration solutions have helped standardize processes and save costs at Lawrenceburg Power.

Case story

### [Eurotherm, Germany – Industry-compliant calibration services for aviation and automotive manufacturing](https://www.beamex.com/about-us/case-stories/eurotherm/)

Paperless documentation including recalibration cycles using the CMX software offers customers a cost effective way of processing and administering data.

Case story

### [EDF Bouchain, France – Innovative calibration management system for a new generation power plant](https://www.beamex.com/about-us/case-stories/edf-bouchain/)

The services provided by Beamex have made it possible to prepare all the data, procedures and tasks to be performed so that the service provider company was operational from the first day of the outage period.

Case story

### [DC Water, USA – Improving quality and accuracy of calibrations](https://www.beamex.com/about-us/case-stories/dc-water/)

Through automated calibration, DC Water has been able to meet the increasing requirements associated with control system upgrades and evolving compliance.

Case story

### [Miami-Dade WASD, USA – Efficient automated calibration procedures](https://www.beamex.com/about-us/case-stories/miami-dade-wasd/)

The combination of multifunctional documenting calibrators and CMX calibration software has automated the entire process at Miami-Dade WASD.

Case story

### [Eni Norge AS, Norway – Accuracy in focus](https://www.beamex.com/about-us/case-stories/eni-norge-as/)

Eni Norge has experienced cost savings and increased profitability thanks to calibrations being made on site instead of outside the house.

```json
{"@context":"https://schema.org","@graph":[{"@type":"WebPage","@id":"https://www.beamex.com/about-us/case-stories/alabama-power/","url":"https://www.beamex.com/about-us/case-stories/alabama-power/","name":"Alabama Power, United States | Beamex CMX and MC6 case story","isPartOf":{"@id":"https://www.beamex.com/#website"},"datePublished":"2022-11-04T13:05:37+00:00","dateModified":"2025-05-13T10:34:17+00:00","description":"Discover how Alabama Power improved their calibration process with Beamex calibrators and calibration software.","breadcrumb":{"@id":"https://www.beamex.com/about-us/case-stories/alabama-power/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https://www.beamex.com/about-us/case-stories/alabama-power/"]}]},{"@type":"BreadcrumbList","@id":"https://www.beamex.com/about-us/case-stories/alabama-power/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.beamex.com/"},{"@type":"ListItem","position":2,"name":"Case stories","item":"https://www.beamex.com/about-us/case-stories/"},{"@type":"ListItem","position":3,"name":"Alabama Power, United States | Beamex CMX and MC6 case story"}]},{"@type":"WebSite","@id":"https://www.beamex.com/#website","url":"https://www.beamex.com/","name":"Beamex","description":"Calibration solutions, calibrators, software and services | Beamex","publisher":{"@id":"https://www.beamex.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.beamex.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https://www.beamex.com/#organization","name":"Beamex","url":"https://www.beamex.com/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https://www.beamex.com/#/schema/logo/image/","url":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","contentUrl":"https://www.beamex.com/app/uploads/2022/06/beamex-logo.svg","width":358,"height":62,"caption":"Beamex"},"image":{"@id":"https://www.beamex.com/#/schema/logo/image/"},"legalName":"Beamex Oy Ab","foundingDate":"1975","description":"Beamex is your trusted partner for calibration excellence, providing accurate measurements, reliable data, and traceability for a safer and less uncertain world.","telephone":"+358 10 550 5000","address":{"@type":"PostalAddress","streetAddress":"Ristisuonraitti 10","postalCode":"68600","addressLocality":"Pietarsaari","addressCountry":"FI"},"sameAs":["https://www.instagram.com/beamexcalibration","https://www.facebook.com/BeamexCalibration","https://www.linkedin.com/company/beamex/","https://blog.beamex.com/","https://www.youtube.com/BeamexCalibration","https://twitter.com/beamexglobal","https://www.crunchbase.com/organization/beamex"],"subOrganization":[{"@id":"https://www.beamex.com/#org-de"},{"@id":"https://www.beamex.com/#org-fr"},{"@id":"https://www.beamex.com/#org-uk"},{"@id":"https://www.beamex.com/#org-us"},{"@id":"https://www.beamex.com/#org-se"},{"@id":"https://www.beamex.com/#org-nl"},{"@id":"https://www.beamex.com/#org-ca"},{"@id":"https://www.beamex.com/#org-cn"}]},{"@type":"Organization","@id":"https://www.beamex.com/#org-de","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex GmbH","telephone":"+49 2161 62115 0","faxNumber":"+49 2161 62115 99","address":{"@type":"PostalAddress","streetAddress":"Am Nordpark 1","postalCode":"41069","addressLocality":"Mönchengladbach","addressCountry":"DE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-fr","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex S.A.S.","telephone":"+33 3 20 04 57 62","address":{"@type":"PostalAddress","streetAddress":"270 Avenue de la République","postalCode":"59110","addressLocality":"La Madeleine","addressCountry":"FR"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-uk","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Limited","telephone":"+44 1455 821 920","address":{"@type":"PostalAddress","streetAddress":"Unit 1, Interchange 21, Centre Court","postalCode":"LE19 1WR","addressLocality":"Leicester","addressCountry":"GB"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-us","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex, Inc.","telephone":"+1 770 951 1927","contactPoint":[{"@type":"ContactPoint","telephone":"+1 800 888 9892","contactType":"customer service","areaServed":"US"}],"address":{"@type":"PostalAddress","streetAddress":"2018 Powers Ferry Road SE, Suite 100","postalCode":"30339","addressLocality":"Atlanta","addressRegion":"GA","addressCountry":"US"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-se","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions AB","telephone":"+46 70 140 54 10","contactPoint":[{"@type":"ContactPoint","telephone":"+46 72 198 03 23","contactType":"sales","areaServed":"Götaland"},{"@type":"ContactPoint","telephone":"+46 70 140 54 10","contactType":"sales","areaServed":"Svealand"},{"@type":"ContactPoint","telephone":"+46 72 198 03 20","contactType":"sales","areaServed":"Norrland"}],"address":{"@type":"PostalAddress","postOfficeBoxNumber":"24103","postalCode":"104 51","addressLocality":"Stockholm","addressCountry":"SE"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-nl","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex B.V.","telephone":"+31 76 799 8606","address":{"@type":"PostalAddress","streetAddress":"Lage Mosten 49-63","postalCode":"4822 NK","addressLocality":"Breda","addressCountry":"NL"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-ca","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Calibration Solutions Ltd.","telephone":"+1 289 424 2639","address":{"@type":"PostalAddress","streetAddress":"2425 Matheson Boulevard East, 8th Floor, Unit 909","postalCode":"L4W 5K4","addressLocality":"Mississauga","addressRegion":"ON","addressCountry":"CA"}},{"@type":"Organization","@id":"https://www.beamex.com/#org-cn","parentOrganization":{"@id":"https://www.beamex.com/#organization"},"name":"Beamex Measurement Technology (Shanghai) Co., Ltd.","telephone":"+86 4000 888 980","faxNumber":"+86 21 6104 1418","address":{"@type":"PostalAddress","streetAddress":"Rm 401, #2 Bldg, 690 Bi Bo Road, Zhangjiang Hi-Tech Park","postalCode":"201203","addressLocality":"Shanghai","addressCountry":"CN"}}]}
```