Next steps

Contact me

Support request

Resource center

Build your Beamex

Free demo

 

 

Download

 

 

Suitable for

  • Plant maintenance engineers and technicians
  • Plants looking to achieve time and cost-savings through having an automated system with documenting calibrators and calibration software
  • Pharmaceutical plants
  • Food & Beverage plants
  • Oil, gas and petrochemical plants and refineries
  • Power plants
  • Service companies
 

 

 

 

Beamex® MC5 Multifunction Calibrator

 

HART Foundation Fieldbus Profibus AMS CMX

 

   compare calibrators

 

Absolute accuracy

  • Replaces several measurement devices
    Due to its all-in-one functionality, the MC5 replaces several individual devices and calibrators. This reduces also recalibration costs, as you only need to maintain one device instead of several devices.
  • Calibrate fieldbus transmitters
    Although modern fieldbus transmitters have been improved compared to older transmitter models, it does not eliminate the need for calibration. The MC5 Fieldbus Calibrator is a combination of a multifunction calibrator and a fieldbus configurator.
  • Accuracy guaranteed
    The MC5 is a high accuracy calibrator. Each MC5 calibrator is delivered with a traceable, accredited calibration certificate.
  • Made for tough use
    The MC5 has IP65-rated robust casing with integrated impact protectors.
  • Modularity means versatility
    The modular construction of MC5 provides flexibility. For instance, the MC5 can be ordered as a pressure or temperature stand-alone calibrator, and then later expand it into a data-logging, documenting multifunction calibrator.
  • Documenting capability
    Calibration results are automatically stored in the memory of the MC5 and calibration results are also automatically transferred from the memory to calibration software. This provides you with a complete documenting calibration system that produces calibration certificates automatically.

Main features (and specifications)

  • Pressure, temperature, electrical and frequency measurement and calibration
  • Modular construction provides future expansion possibilities
  • Pressure (1 year uncertainty):
    from 0.025 % rdg + 0.01 % FS
  • Temperature (1 year uncertainty):
    from 0.06°C (RTD measurement)
  • Temperature (1 year uncertainty):
    from 0.10°C (TC measurement)
  • Electrical (1 year uncertainty):
    typically 0.02 % rdg + small adder
  • Support for Foundation Fieldbus H1, Profibus PA and HART®
  • Multilingual user-interface
  • Warranty: 3 years for MC5, 1 year for battery pack

 

Applications:
Pressure
  • Gauge pressure measurement
  • Absolute pressure measurement
    (with barometric option)
  • Low differential pressure measurement
 
Temperature
  • RTD measurement / simulation
  • TC measurement / simulation
Electrical
  • Resistance measurement / simulation
  • Voltage measurement / generation
  • Current measurement /generation
  • Frequency measurement / generation
  • Pulse counting/generation
  • 24 VDC loop supply
  • Switch sensing

 

 

Customer comments:
New England Controls, USA
"The time required to calibrate field control devices, and to produce test results, has been reduced by between half or two-thirds compared to older, more conventional methods."
Field Service Engineer
Hakon Dybwad

 

Georgia Power’s Plant Yates, USA
"Beamex equipment was chosen because the MC5 offered the most options as far as module ranges, devices that could be calibrated and put into the database, HART® communications, and database functionality."
Senior I & C Technician, Jeff Cason