3 versions:
- MC2 Pressure/Electrical Calibrator
- MC2 Temp./Electrical Calibrator
- MC2 Multifunction Calibrator
Internal / external pressure modules
Compact size and design
User-friendly
| |
| |
Internal pressure module |
|
- |
|
| |
Connection for external pressure modules |
|
|
|
| |
Current measurement (with internal and external
supply) |
|
|
|
| |
Voltage measurement |
|
|
|
| |
Frequency measurement |
|
|
|
| |
Pulse counting |
|
|
|
| |
Switch sensing |
|
|
|
| |
Internal HART® compatible 24 VDC loop supply |
|
|
|
| |
Current generation (with internal and external
supply) |
- |
|
|
| |
Voltage generation |
- |
|
|
| |
Frequency generation |
- |
|
|
| |
Pulse generation |
- |
|
|
| |
mV measurement / simulation |
- |
|
|
| |
Resistance measurement / simulation |
- |
|
|
| |
RTD measurement / simulation |
- |
|
|
| |
TC measurement / simulation |
- |
|
|
MC2-PE = Pressure / Electrical Calibrator
MC2-TE = Temperarture / electrical Calibrator
MC2-MF = Multifunction Calibrator
When calibrating a transmitter, the transmitters output may be displayed
in an error % unit rather than in an engineering unit.
When calibrating a transmitter, the transmitter's output may be displayed
as error in input or output engineering units.
Any measurement may be presented as a percent within the user-programmable
range.
A versatile, programmable scaling function allows the user to scale any
measured unit into any custom unit. Scaling also includes a rooting transfer
function for flow applications.
The unit has several user-configurable setups that make it easy to save
and quickly recall the desired configuration.
The leak test function indicates the pressure drop and leak rate during
the user-programmable period.
The unit includes versatile and programmable automatic step and ramp generation
function, as well as manual step function.
Any measurement can be programmed to have an alarm based on the measurement
value or on its rate of change.
Programmable damping allows the user to select different filterings for
the measurements.
The bar graph allows the user to display the measurement or generation
as an analogue bar, including programmable starting and ending points.
Difference measurement allows the user to measure the difference between
two pressure modules.
The deviation function allows the user to display a deviation between
a given reference value and the actual measurement.
Redundancy measurement allows the user to measure the same pressure using
two pressure modules (internal and external) simultaneously. The units
alarms sounds if the readings excessively differ from each other.
The unit also allows the user to view various pieces of additional additional
information such as Min / Max / Rate / Internal temperature / Thermocouples
thermovoltage / RTD sensors resistance /, etc.