Features:

Main and other features
Error % display
Error display in input or output units
%-display
Scaling
User setups
Leak testing
Step and ramp
Programmable alarms
Damping
Bar graph
Difference
Deviation
Redundance
Additional Information

Main features:

• 3 versions:
     - MC2 Pressure/Electrical Calibrator
     - MC2 Temp./Electrical Calibrator
     - MC2 Multifunction Calibrator
• Internal / external pressure modules
• Compact size and design
• User-friendly

Feature comparison:

  Features MC2-PE MC2-TE MC2-MF
  Internal pressure module -
  Connection for external pressure modules
  Current measurement (with internal and external supply)
  Voltage measurement
  Frequency measurement
  Pulse counting
  Switch sensing
  Internal HART® compatible 24 VDC loop supply
  Current generation (with internal and external supply) -
  Voltage generation -
  Frequency generation -
  Pulse generation -
  mV measurement / simulation -
  Resistance measurement / simulation -
  RTD measurement / simulation -
  TC measurement / simulation -

MC2-PE = Pressure / Electrical Calibrator
MC2-TE = Temperarture / electrical Calibrator
MC2-MF = Multifunction Calibrator

back to top


Error % display
When calibrating a transmitter, the transmitter’s output may be displayed in an error % unit rather than in an engineering unit.

Error display in input or output units
When calibrating a transmitter, the transmitter's output may be displayed as error in input or output engineering units.

%-display
Any measurement may be presented as a percent within the user-programmable range.

Scaling
A versatile, programmable scaling function allows the user to scale any measured unit into any custom unit. Scaling also includes a rooting transfer function for flow applications.

User setups
The unit has several user-configurable setups that make it easy to save and quickly recall the desired configuration.

Leak testing
The leak test function indicates the pressure drop and leak rate during the user-programmable period.

Step and ramp
The unit includes versatile and programmable automatic step and ramp generation function, as well as manual step function.

Programmable alarms
Any measurement can be programmed to have an alarm based on the measurement value or on its rate of change.

Damping
Programmable damping allows the user to select different filterings for the measurements.

Bar graph
The bar graph allows the user to display the measurement or generation as an analogue bar, including programmable starting and ending points.

Difference
Difference measurement allows the user to measure the difference between two pressure modules.

Deviation
The deviation function allows the user to display a deviation between a given reference value and the actual measurement.

Redundance
Redundancy measurement allows the user to measure the same pressure using two pressure modules (internal and external) simultaneously. The unit’s alarms sounds if the readings excessively differ from each other.

Additional Information
The unit also allows the user to view various pieces of additional additional information such as Min / Max / Rate / Internal temperature / Thermocouple’s thermovoltage / RTD sensor’s resistance /, etc.